https://issues.apache.org/jira/browse/HDDS-7463?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
ASF GitHub Bot updated HDDS-7463:
---------------------------------
Labels: pull-request-available (was: )
> SCM Pipeline scrubber never able to cleanup allocated pipeline
> --------------------------------------------------------------
>
> Key: HDDS-7463
> URL: https://issues.apache.org/jira/browse/HDDS-7463
> Project: Apache Ozone
> Issue Type: Bug
> Components: SCM
> Reporter: Sumit Agrawal
> Assignee: Sumit Agrawal
> Priority: Major
> Labels: pull-request-available
> Attachments: image-2022-11-07-19-17-20-807.png,
> image-2022-11-07-19-18-41-408.png, image-2022-11-07-19-19-30-448.png
>
>
> Pipeline is created and remains in allocated state, never able to remove from
> SCM. This is stuck as time library used are different and never able to work.
> 1. Time compared with current is always negative. as clock used is from
> hadoop time package which make use of System.nanoTime(), while java.util time
> package make use of different function. Both can not be used together.
> !image-2022-11-07-19-17-20-807.png|width=750,height=240!
> !image-2022-11-07-19-18-41-408.png|width=750,height=250!
> !image-2022-11-07-19-19-30-448.png|width=750,height=250!
> As per below link, System.nanoTime() is used to measure elapsed time, so can
> be useful for time taken by method, but not as part of time of system.
> [https://stackoverflow.com/questions/32443254/how-can-i-convert-the-result-of-system-nanotime-to-a-date-in-java]
--