>I'm still puzzled, since small delays don't work for me either. And I do work 
>the third (vdd) line. When the conversion is running and I read the device, 
>the reported temperature is 85 degrees. So I have to wait for 800ms - one way 
>or the other - after conversion before I can get a valid reading. 

Just some thoughts...

If you're reading only occasionally, do this:
- start conversion
- wait some time, depending on selected resolution
- read value

If you're reading continuously, do this:
- read value from last conversion
- start new conversion
- rely on the main program not to read again before the conversion has finished

Greets,
Kiste


-- 