ok, here's another one to try (after init like the others)... You should get 04FFFFFFFF on your standard capacity card. Bit 2 of the first byte should be set as it is on mine 0b00000100.
High capacity cards should return something else, although 2 high capacity cards I have tried are not giving me what I am expecting. I get 0000000000 on my high capacity, but should get something like 010001AA00 procedure sd_read_if_cond() is sd_chip_select = low -- enable the sd card var byte response send_command(SD_SEND_IF_COND, 0x1AA, response) print_byte_hex(serial_data,response) print_byte_hex(serial_data,spi_master) -- Get a responce from the card after each command print_byte_hex(serial_data,spi_master) -- Get a responce from the card after each command print_byte_hex(serial_data,spi_master) -- Get a responce from the card after each command print_byte_hex(serial_data,spi_master) -- Get a responce from the card after each command spi_master = 0xFF -- send 8 clock pulses sd_chip_select = high -- enable the sd card end procedure sd_read_if_cond() -- You received this message because you are subscribed to the Google Groups "jallib" group. To post to this group, send email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/jallib?hl=en.