byungwoojun [http://community.jboss.org/people/byungwoojun] created the 
discussion

"Re: A bug? Ksession.signalEvent and ProcessInstanceWaitingForEvent"

To view the discussion, visit: http://community.jboss.org/message/609670#609670

--------------------------------------------------------------
To me, that the name query ProcessInstanceWaitingForEvent used by the 
ksession.signalEvent does NOT return with the correct process/subprocess 
instance which has the intermediate event type when there are some left-over 
data entries in the EventType database table due to:

- multiple process instances for the same process defintion are running (i.e., 
there are more data entries in the EventType database table). Of course, the 
process instances have the same event type name. 
- previous sessions failed and didn't clean up data entries from the EventType 
database table.

There could be several ways to solve this. At this time, my team didn't want to 
add additional column to the database table, we solved the issues as follows: 

1. When we start the process, we store a unique correlation id, a session id 
and a process instance id (it will be the top-level process instance id) in a 
database table (e.g., correlation id, session id, process instance id). 

2. When an intermediate message arrives, we restore the session using the 
incomig correlation id from the database table. Using this table, we also find 
the top-level process instance id. 

3. Using this process id, we query the EventType database table to find the 
process or sub-process which has the proper event type. The EventTypes database 
table has two columns: instance id and element. 

e.g.,
InstanceID              Element
-----------------------------------------------------------------------------------
1356                       processInstanceCompleted:1357
1357                       eventType1

As you can see, the 1356 row points the 1357 row. In my opinion, the proper way 
to find a correct pid is drilling down the chain from the top-level pid which 
is getten from the startProcess. Instead of embedding the next pid part of the 
text data in the Element field, if we have the third column to point the next 
pid, we could use SQL chain query. Using the current schema, I need to get the 
356 instance id, parse the element text (after the colon), then, get the row 
1357 instanceid, so on....

Since we don't want to add additional column at this time, we created a 
function with two parameters: eventType, topLevelProcessInstanceId:

- the function queries the EventType database table using the 
topLevelProcessInstanceId.
- it parses the element column. 
     - If the element contains the same eventType, it returns the 
processInstanceId.
     - Otherwise, it gets a sub-string after ":" (e.g., 1357). Use this 
sub-string (need to convert it to long) as a parameter along with the eventType 
(unchanged), and call the same function recursively until the element is equal 
to the event type.  

4. After the function, we call ksession.signalEvent(eventType, eventData, 
foundProcessInstanceId);

As you noticed, this method may end up querying multiple times depending on the 
depth of sub-processes. There could be some performance penalties. But, it 
works reliably regardless the EventTypes database table entries. 

If jBPM engine itself supports the correlation out-of-the-box, it would be 
great. But for now, we need to code for the correlation support.

Any suggestions would be appreciated.

bwj

--------------------------------------------------------------

Reply to this message by going to Community
[http://community.jboss.org/message/609670#609670]