How do I cancel Old data monitor and what does it impact? 

On Tuesday, October 8, 2013 2:37:15 PM UTC+2, vjuranek wrote:
>
> On Tuesday 08 October 2013 14:11:01 Christoph Kutzinski wrote: 
> > Caan you open a JIRA issue against the plugin? 
>
> while this could be fixed by changes in plugin (probably by fixing 
> backward 
> compatibility), the root cause seems to be Old data monitor which keeps 
> all 
> old data in memory, which can quite easily cause OOM. Even worse, it *may* 
> happen that Old data monitor automatically turn on even if it was manually 
> turned off before. I observed it on one of our Jenkins instance where OOM 
> happened quite often because of Old data monitor, but haven't had enough 
> time 
> to investigate it yet. 
>
> @Ohad - quick fix could be disable Old data monitor and turn it on once 
> plugin 
> is fixed. You can also check if it turn back on itself to 
> confirm/disapprove my 
> observation above

-- 
You received this message because you are subscribed to the Google Groups 
"Jenkins Developers" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/groups/opt_out.

Reply via email to