I've tried to use unit 1024 (as it fits in the range described) and
when I do a commit check I get the following error:
[EMAIL PROTECTED] commit check
[edit interfaces ge-0/0/1]
'unit 1024'
Only unit 0 is valid for this encapsulation
error: configuration check-out failed
You are right. With encapsulation "ethernet-ccc" you have to use unit 0.
You have to use unit from 512 to 4095 with encapsulation "vlan-ccc".
Sorry about it.
Regarding the Route Distinguisher, I thought that it must be the same
on both CEs so that they'll know it's traffic destined for a given
routing instance.
The route-distinguisher must be different on each PE. A PE know where it
must send traffic with this command :
vrf-target target:65102:100;
Regards,
Samuel