Hello > You can see it as "show chassis fpc detail" command. > The fpc with I/O Manager v2.0 is enhanced one. > > r...@m160> show chassis fpc detail > Slot 2 information: > State Online > Temperature 40 degrees C / 104 degrees F > Total CPU DRAM 32 MB > Total SRAM 4 MB > Total SDRAM 256 MB > I/O Manager ASIC information Version 2.0, Foundry IBM, Part number 0 > ^^^^^^^^^^^^^
In the working Setup with a M40e: Slot 7 information: State Online Temperature 42 degrees C / 107 degrees F Total CPU DRAM 32 MB Total SRAM 4 MB Total SDRAM 128 MB I/O Manager ASIC information Version 3.0, Foundry IBM, Part number 0 I/O Manager ASIC information Version 3.0, Foundry IBM, Part number 0 Start time 2010-01-19 17:06:23 CET Uptime 19 days, 19 hours, 8 minutes, 23 seconds In the NOT working Setup with the M160: Slot 7 information: State Online Temperature 37 degrees C / 98 degrees F Total CPU DRAM 32 MB Total SRAM 4 MB Total SDRAM 256 MB I/O Manager ASIC information Version 2.0, Foundry IBM, Part number 0 I/O Manager ASIC information Version 2.0, Foundry IBM, Part number 0 I/O Manager ASIC information Version 2.0, Foundry IBM, Part number 0 I/O Manager ASIC information Version 2.0, Foundry IBM, Part number 0 Start time 2010-01-19 17:05:41 CET Uptime 19 days, 19 hours, 9 minutes, 14 seconds Im wondering why there is no hint in the syslog, if the hardware version would be the cause. And there is no verify when the RP try to access the service... Regards, -- Mit freundlichen Gruessen Dipl. Ing. A. Schweder Gutachten & Consulting Mobil +49.177.2194627 (+49.160.97639300) _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp