On Tue, 9 Feb 2010, Paul Waller wrote:
I'm wondering if anybody has seen this issue before. We have a EX 3200
running JunOS 9.2R2 release. Everytime the switch looses power it boots
back up OK but no ARP entries are seen. I haven't had a chance to see
the logs yet but I'm informed this has been happening for sometime & a
2nd reboot of the switch fixes the problem.
Once I look at the config & get the logs then I might post some more but
I thought I'd just post this question just in cast somebody had seen
is there a loopback filter on the device? apparently prior to
9.5<something> on the ex juniper thought filtering ARP in an L3 filter was
'acceptable'...