> On M/T-series you need a tunnel PIC to provide an lt interface.

Not necessarily. From an M7i with built-in ASP (i.e. the built-in
version of the AS PIC):

FPC 1                                                    E-FPC
  PIC 2          REV 05   750-015931   PX6751            ASP - Integrated 
(Layer-2-3)

[email protected]> show interfaces lt-1/2/0
Physical interface: lt-1/2/0, Enabled, Physical link is Up
  Interface index: 140, SNMP ifIndex: 511
  Type: Logical-tunnel, Link-level type: Logical-tunnel, MTU: Unlimited, Speed: 
800mbps
  Device flags   : Present Running
  Interface flags: Point-To-Point SNMP-Traps
  Link flags     : None
  Physical info  : 13
  Current address: 00:1f:12:a5:a4:bc, Hardware address: 00:1f:12:a5:a4:bc
  Last flapped   : 2009-11-26 01:00:02 CET (16w4d 16:06 ago)
  Input rate     : 0 bps (0 pps)
  Output rate    : 0 bps (0 pps)

Steinar Haug, Nethelp consulting, [email protected]
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp