On 07/11/2010 12:05 AM, John Wilkes wrote:
On Sun, Jul 11, 2010 at 12:28 AM, Phil Mayers<[email protected]>  wrote:
Your direct test I would expect to fail; pulling the TX fibre will cause the
far end to signal fault and bring the entire link down.

Yes, the far end. But I meant I connected both TX and RX between two ports.
That made them both come up (of course). But when I pulled just one TX
they both went down.

As far as I understand it, that is expected if autoneg is enabled. If you pull the TX link on switch A, switch B will see the loss of light, signal link-fail, and switch A will then put its link down.

Anyway, it sounds like you've covered the obvious things, and if it works with other vendors, I guess it's something specific to the EX. Can't help there, sorry.
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to