I was wondering what folks might be using for interface hold timers when 
introducing a L1 (optically) protected circuit between two nodes?  These would 
be MX960s and T640s terminating the circuits.   The transport gear in our case 
does drop light on the transponder during a protection event with restoration 
typically <50ms.  The default hold timers appear to be 0, so they will need to 
be adjusted so we do not trigger FRR during the optical restoration time.  

Thanks, 

Phil  