Thank you very much for your help.

Both RE´s have the same software image. and now my doubts are about the configuration, Do I need to edit groups RE0 and re1? In this moment I haven´t IP in the fxp0 interface, How I can access the Backup RE from the Master RE ?.

Best regards



El 08/03/2012 4:20, Chris Cappuccio escribió:
Same software image? Perfect, just plug it in. It will copy its main config from the 
master when you plug it in. "set system commit synchronize" and commits will 
get saved to both REs automatically.

Juniper GOWEX [[email protected]] wrote:
Hello,

We purchased a second RE600 (we had only one RE600). Does anyone
know a procedure for adding a second RE?. The new RE has the same
version and configuration as the RE installed. Do you have any
recommendations of previous changes in the configuration? .