Hiya bud Yes that can work here.
Just make sure that the SRXs are less than 100ms apart and each sync connection, both fabric and control, is on separate VLANs. HTH On 16 July 2012 10:04, Spam <[email protected]> wrote: > Is it possible to connect 2 SRX devices together into a HA Cluster by > connecting > the Control & Fabric Interlinks via switches or must they be directly > connected. > > My planned setup is as follows: > > SRX<->Switch<->10GB Xconnect<->Switch<->SRX > > I can also give each connection is own dedicated VLAN if that would help. > > Spammy > > > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp > _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp