Ben Dale wrote:
> 
> Something like this should do the trick once you've configured it on both 
> ends:
> 
> set protocols oam ethernet link-fault-management action-profile UDLD event 
> link-adjacency-loss
> set protocols oam ethernet link-fault-management action-profile UDLD action 
> syslog
> set protocols oam ethernet link-fault-management action-profile UDLD action 
> link-down
> set protocols oam ethernet link-fault-management interface ge-0/0/23.0 
> apply-action-profile UDLD
> 
> We had a similar issue to solve at some sites connected via Free-Space Optics 
> units.

Ben, thanks a lot, it works. The interface goes down as expected.


-- 