https://bugs.kde.org/show_bug.cgi?id=527129
Bug ID: 527129
Summary: Wrong gamma applied to the second monitor which
displays still full screen image
Classification: Plasma
Product: kwin
Version First 6.8.0
Reported In:
Platform: Other
OS: Linux
Status: REPORTED
Severity: normal
Priority: NOR
Component: platform-drm
Assignee: [email protected]
Reporter: [email protected]
CC: [email protected]
Target Milestone: ---
DESCRIPTION
Wrong gamma(?) applied to the second monitor which displays still full screen
image
STEPS TO REPRODUCE
1. Turn on two monitors, make sure:
- it has built-in or ICC profile enabled
- night light is turned off
- it's empty (Plasma bar is hidden and no windows are open) or has full screen
application which doesn't refresh anything (e.g. paused video player)
2. Move mouse across monitors (or click and move)
OBSERVED RESULT
Gamma changes significantly (it's much "brighter") when mouse leaves the
monitor
EXPECTED RESULT
No gamma changes
SOFTWARE/OS VERSIONS
Operating System: 7.2.10-1-cachyos (64-bity), RDNA2 dGPU
KDE Plasma Version: 6.8.0
KDE Frameworks Version: 6.31.0
Qt Version: 6.12.0
--
You are receiving this mail because: