https://bugs.kde.org/show_bug.cgi?id=527712
Bug ID: 527712
Summary: Overlapping Lifeline Boxes in Sequence Diagrams
Classification: Applications
Product: umbrello
Version First Git
Reported In:
Platform: Other
OS: Linux
Status: REPORTED
Severity: normal
Priority: NOR
Component: general
Assignee: [email protected]
Reporter: [email protected]
Target Milestone: ---
Created attachment 197587
--> https://bugs.kde.org/attachment.cgi?id=197587&action=edit
Figure that ilustrate the problem
DESCRIPTION
When creating a sequence diagram that includes a nested call (see Figure A in
attachment), clicking on the top of the enclosing lifeline box (see Figure B)
causes the enclosing box to overlap the nested one.
STEPS TO REPRODUCE
1. Create a sequence diagram with a nested call into a lifeline box (see figure
A)
2. Click on the top of the enclosing lifeline box
OBSERVED RESULT
The enclosing box overlaps the nested one.
EXPECTED RESULT
The enclosing lifeline box should not overlap the nested lifeline box.
SOFTWARE/OS VERSIONS
Operating System: KDE neon User Edition
KDE Plasma Version: 6.8.1
KDE Frameworks Version: 6.31.0
Qt Version: 6.11.1
ADDITIONAL INFORMATION
The arrow representing the nested call is displayed as an asynchronous message
arrow. However, it should be displayed as a synchronous message arrow, with a
filled arrowhead.
--
You are receiving this mail because: