Hi Marcus,

 

You did nothing wrong, the DRC in PCBNEW doesn't detect zone connections. I
usually run thin tracks between the ground pins and DRC before filling the
zones just to make sure.

 

Regards,

 

MarkW

 

From: [email protected] [mailto:[EMAIL PROTECTED] On
Behalf Of avr4you
Sent: 29 August 2008 18:16
To: [email protected]
Subject: [kicad-users] Net not connected with Zone Fill

 

Hello,

i have finished my first project with the latest SVN Kicad Version.
At last i have added a zone fill to connect the GND net.
I see that all GND Pads are connected but the DRC shows always
that the GND net is still not connected.
What's my mistake?

Regards,

Marcus

 