Great, that works!

Thanks, David!

--- In [email protected], "yajeed2000" <[EMAIL PROTECTED]> wrote:
>
> --- In [email protected], "tom_iphi" <iphi@> wrote:
> >
> > Hi,
> > 
> > I encounter the following problem:
> > In my schematic, I use the standard DB9 connector to provide 
power and 
> > GND. In the KiCAD lib, the DB9 connector is defined with 9 
passive pins.
> > 
> > Thus I get two ERC errors:
> > 
> > ERC: Warning Pin power_in not driven (Net 7) (X= 5,900 inches, Y= 
3,200 
> > inches
> > 
> > , one for GND and one for VCC.
> > 
> > Do I need a special connector edition for each application or is 
there 
> > another way to tell eeschema, that GND and VCC are actually 
driven 
> > through the DB9 connector?
> > 
> > Thanks, Tom
> >
> Hi,
> Just add a 'power flag' symbol to both GND and VCC. This should cure
> the problem.
> 
> David.
>


Reply via email to