Pedro & Bill, You are correct. I tried this and it works.
This seems to be a poor way to do this since any time I use this IC I will have to manually edit each pin. Luckily this particular one only has 4 pins. And since there is no way to visibly detect changes in PCBnew you have to check each pin in a Gerber viewer. Since you have both done this, what is your opinion on how a fix should be implemented? I think the module editor should implement this. I initially was thinking that the editor should just allow you to change the mask clearance. But I am wondering if also allowing another type of pad "BGA" would make better sense. Thanks and regards, Doug --- In [email protected], "Doug Deeds" <[EMAIL PROTECTED]> wrote: > > If I understand correctly, this only changes the mask clearance around > vias and traces. I need to change the clearance around the pads in > the module editor. > Doug > > --- In [email protected], "bill Randall" <Bill.Randall@> > wrote: > > > > Hi, > > I had the same problem - the PCB manufacturer said there was too > much overlap of mask over pad. > > This can be set as follows in PCBNEW: > > Go to Dimensions (top tool bar) > > Go to Tracks and Vias > > Set "Mask clearance" as required (I used 0.004 and PCB manufacturer > is happy with that) > > Bill > > UCT > > > > >>> Pedro Martin <pkicad@> 11/11/2008 06:22 PM >>> > > > > Hi, > > > > Dimensions->Tracks and vias -> Mask clearance > > > > Regards, > > Pedro. > > > > > Maybe I missed this in the documentation, but I can't figure out > how to > > > change the solder mask opening size. > > > > > > I am laying out a 4 bump chip scale package and the default mask > opening > > > is too large. How do I change this dimension? > > > > > > Regards, > > > Doug Deeds > > > Forthright Solutions > > > 817 230 4483 > > > > > > > > >