Thanks, Seems I will have to do the same thing.
Wei ________________________________ From: Greg Dyess <[email protected]> To: [email protected] Sent: Friday, August 21, 2009 3:54:56 PM Subject: Re: [kicad-users] Via in Pad result in unconnected status I ran into exactly the same problem, but it only seemed to be manifest if the pad was on the copper side. I found no work-around than to move the via slightly off-center and then connect it to the pad. Greg ________________________________ From: weilu0 <wei...@yahoo. com> To: kicad-users@ yahoogroups. com Sent: Friday, August 21, 2009 1:55:23 PM Subject: [kicad-users] Via in Pad result in unconnected status I have a dense board which requires put via on pads of the by-pass capacitors. But somehow those pads are always listed as unconnected although there is a via on the pad and then connected to where it needs to be connected. Now it is towards the end of layout and I have difficulty using the DRC to check the unconnected, because there is always this hundreds of pads that has via on it listed as unconnected. Any fixes, suggestions, work-around are appreciated. Regards, Wei ------------ --------- --------- ------ Please read the Kicad FAQ in the group files section before posting your question. Please post your bug reports here. They will be picked up by the creator of Kicad. Please visit http://www.kicadlib.org for details of how to contribute your symbols/modules to the kicad library. For building Kicad from source and other development questions visit the kicad-devel group at http://groups. yahoo.com/ group/kicad- develYahoo! Groups Links