Never mind -- didn't catch that it was a footprint issue. I'm not reading those yet :(
But I can catch some ERC errors that the internal eeschema ERC doesn't. Right now the two ERCs are complementary. Pat --- In [email protected], "Patrick" <pmau...@...> wrote: > > > This is exactly the sort of thing my Python scripts (kipy.org) should catch. > If you run them on you failing board, they should help pinpoint problems like > this. > > Regards, > Pat > > --- In [email protected], "kendall.crews" <k.crews.1@> wrote: > > > > I'm working on a dual H-Bridge motor controller Arduino shield. I have the > > circuit complete in EESchema and the ERC is happy and all that good stuff. > > In PCBnew, I'm able to import all my components by reading the netlist, but > > not everything is connected by the rat nest. > > > > Interestingly enough, its only the MOSFETs that didn't get connected. Eight > > TO220 and four TO92. Everything else seems to be connected correctly. > > > > Any ideas? I'm very new to KiCad (been using it for a whole 8 hours now), > > so it's very likely I've just done something wrong. I can post screenshots > > if that would help. Thanks! > > >