At 05:10 PM 2/14/2012, you wrote:
>   My system just has two transfer pumps and 2 main pumps to the 
> EFS-3.  All this talk about connecting vents seems like it's just 
> complicating a system that does not have to be complicated.  I like 
> the idea of copying the Ercoupe or even the Piper systems so as to 
> not re-invent the wheel to much.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

My system is the safest and most simple setup I could come up 
with.  I have no header tank at all.  All my fuel is in the outer 
wing panels in long narrow tanks just behind the forward spar.  I 
have a line coming to the fuselage from each tank with a shut off 
valve for each tank.  The valves are located on the forward face of 
the forward spar between my legs.  Between the shutoff valves is a 
tee that goes to two fuel pumps in series, to a pressure regulator, 
to the gascolator on the firewall, and then to the carb.  I have no 
engine driven pump so I have a back up battery in case I lose 
electrical power.  I can pump from either or both tanks with either 
or both pumps.  It is just a matter of turning on one or both pumps 
and one or both tanks.  I can carry 12.5 gallon in each wing and my 
C.G. moves forward 1 inch from full to empty tanks.

Larry Flesner

Reply via email to