Had something similar to this happen once. The KSU
and station wiring were punched into 66M blocks which
were near a furnace. Over time, this must have
deposited just enough _conductive_ debris that the
wiring for one station would short out. Naturally,
only in certain weather, only after I'd leave the
site, etc... I replace the punchdown block and
no problems for one month. I later replace all the
66 blocks and rigged a cover for the area.
---- Mark Vogel <[EMAIL PROTECTED]> wrote:
> We have a KX-T123211D in our home and all of a
sudden we're having
> problems with phones attached to two of our jacks
(after three
> years). The phones appear dead, however if I
sometimes jiggle the
> wires, the phones get dial tone and can operate for
a while. If I
> move the phones to other jacks in the house, they
seem to work fine.
> I've brought phones from other parts of the house
and they have the
> same problem when plugged into these two jacks.
I've tried changing
> the cords, but the same problem.
>
> Anyone have any idea of what could go wrong after
several years.
> Could it be the board?
>
>
>
>
>
>
******************************************************
***
> * To unsubscribe, e-mail kxt-
[EMAIL PROTECTED] *
> * The KXT-Digest Home Page:
http://kxthelp.com/ *
>
******************************************************
***
>
>
*********************************************************
* To unsubscribe, e-mail [EMAIL PROTECTED] *
* The KXT-Digest Home Page: http://kxthelp.com/ *
*********************************************************