Had something similar to this happen once. The KSU
and station wiring were punched into 66M blocks which
were near a furnace. Over time, this must have 
deposited just enough _conductive_ debris that the
wiring for one station would short out. Naturally,
only in certain weather, only after I'd leave the
site, etc...  I replace the punchdown block and
no problems for one month. I later replace all the
66 blocks and rigged a cover for the area.


---- Mark Vogel <[EMAIL PROTECTED]> wrote:
> We have a KX-T123211D in our home and all of a 
sudden we're having 
> problems with phones attached to two of our jacks 
(after three 
> years).   The phones appear dead, however if I 
sometimes jiggle the 
> wires, the phones get dial tone and can operate for 
a while.  If I 
> move the phones to other jacks in the house, they 
seem to work fine. 
> I've brought phones from other parts of the house 
and they have the 
> same problem when plugged into these two jacks.  
I've tried changing 
> the cords, but the same problem.
> 
> Anyone have any idea of what could go wrong after 
several years. 
> Could it be the board?
> 
> 
> 
> 
> 
>        
******************************************************
***