Subject: KX-T: Seem`s like ... .
> Hello All!
> Seems like I`m bored so many people on the net, but I`m really in trouble.
> I have 2 KX-TD1232 connected in Master/Slave circut. Cool? But when I`m
connect 2 X 4 CO line expansion (1/1) and 4 X 16SLT expansion(2X2)and enter
right codes in 109 and power down/up my system is working wrong. When CO
lines work - SLT doesn`t work and reverse.
> WHERE IS MY MISTAKE? I`m don`t sleep last night. My boss ready to kill me
8-E
>
> HEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEELP!
When you power down / up are you allowing them to have their little "bonding
session" without ANY interruptions for a few minutes or so. If you have
already done this, please excuse me, but it is surprising how often people
take the instructions on the Pans "bonding" with a pinch of salt - yet it is
vital to get it right.
If there is *ANY* chance of a call coming in, an extension being lifted or a
doorphone being pressed etc, wait until the system can be off-line for a
while (perhaps late evening?) and then disconnect the CO lines coming in and
pull the amphenol connectors which connect up the extensions.
Power down both cabinets, wait a few seconds (say 10 ?) until all the relays
have dropped out, then check that *NOTHING* can make the system do any work
at ALL.
Check one is set for slave and one for master and that the link is in place
and secure
Power the units back on together.
Go and have a cup of coffee and an optional fag - take you time.
Reconnect amphenol connectors and CO line jacks.
Test it again. If there is still problem, get back to the group.
Mark
*********************************************************
* To unsubscribe, e-mail [EMAIL PROTECTED] *
* The KXT-Digest Home Page: http://kxthelp.com/ *
*********************************************************