Hi l2switch devs,

Here is my analysis on CSIT failures:

- Address Tracking and Loop Removal test issues are not reproducible outside 
ODL infra, therefore these are not blocker and maybe not even bugs. Still some 
infra investigation is required here as same tests are passing for Beryllium.

- Issue with host scalability is due to recent regression: l2switch does not 
push flood flows on single switch: 
https://bugs.opendaylight.org/show_bug.cgi?id=6573 
<https://bugs.opendaylight.org/show_bug.cgi?id=6573>