Actually, it shouldn't work every time.  If you have two identical FFTs
with opposite phases, adding the complex FFTs will cancel them out.  You
would lose data if you add up all the complex FFTs, and the "average"
value would be smaller than the correct value.

Bruce

------------------------------------------
Bruce Ammons
Ammons Engineering
www.ammonsengineering.com
(810) 687-4288 Phone
(810) 687-6202 Fax



-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Dr Sanjay Gupta
Sent: Wednesday, February 04, 2004 5:49 AM
To: Gerd Rech
Cc: [EMAIL PROTECTED]
Subject: Re: [W6.1] RMS averaging with "FFT Spectrum (Mag-Phase).vi"


Gerd,

Why not just add up the complex fft's of the various segments prior to
computing the magnitude and phase. Works every time.

Sanjay Gupta

+---------------------------------------------------------------------+