Hi,

> The current lcms measurement tool does not support it. Is the support 
> of the HCT target
> just a question of the measuremen tool?

To support any new target, you need two things:

a) The IT8 reference sheet from the target manufacturer
b) A picker template to specify patches layout for measurement
tool.

a) is usually available from all vendors, and b) can be done with a
little patience. If you take a look on "templates" directory, there
are the definitions of target layouts, as *.ITX Measurement tool 
does read these files to generate the pick shapes.

Templates are very alike IT8 files, they are human-readable and  
instead of Lab colors, they have patch sizes. Coordinates are given 
in 0..65535 domain, measurement tool does resize them to suitable 
values depending on resolution

Regards,
Marti.




----- Original Message ----- 
From: <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Thursday, February 06, 2003 11:52 PM
Subject: [Lcms-user] Hutch Color Scanner Calibration Target


> Hello,
> 
> I just found the HCT scanner calibration target. It is a new high 
> precision scanner target.
> More info under http://www.hutchcolor.com/hct.htm
> 
> The current lcms measurement tool does not support it. Is the support 
> of the HCT target
> just a question of the measuremen tool?
> 
> Regards
> Juergen
> 
> 
> 
> -------------------------------------------------------
> This SF.NET email is sponsored by:
> SourceForge Enterprise Edition + IBM + LinuxWorld = Something 2 See!
> http://www.vasoftware.com
> _______________________________________________
> Lcms-user mailing list
> [EMAIL PROTECTED]
> https://lists.sourceforge.net/lists/listinfo/lcms-user
> 
> 



-------------------------------------------------------
This SF.NET email is sponsored by:
SourceForge Enterprise Edition + IBM + LinuxWorld = Something 2 See!
http://www.vasoftware.com
_______________________________________________
Lcms-user mailing list
[EMAIL PROTECTED]
https://lists.sourceforge.net/lists/listinfo/lcms-user

Reply via email to