On 05/24/2016 06:54 AM, Marco Freudenberger wrote: > Hi! > > I'm trying to create a gray profile that has an L* (L-star) response > curve, but I'm a little confused about the "parametric tone curve" syntax. > > Is there an example how to create the correct tone curve? I guess I need > the inverted version of L* companding, right? Would that be a 4 > parametric curve, with: > > y(Gamma) = 3.0 > > a=1.0/1.16 > > b=0.16/1.16 > > c=100.0/903.3 > > d=0.008856*903.3/100.0 > > So in code something like that: > > cmsFloat64Number lStarParams[5] = { 3.0, 1.0/1.16, 0.16/1.16, > 100.0/903.3, 0.008856*903.3/100.0 }; >
FWIW (I'm no expert!), I use these parameters to make the Lab parametric curve: cmsFloat64Number labl_parameters[5] = { 3.0, 1.0/1.16, 0.16/1.16, 2700.0/24389.0, 0.08000 }; The parameters are from these two pages: http://brucelindbloom.com/index.html?Eqn_RGB_to_XYZ.html http://brucelindbloom.com/index.html?LContinuity.html Where does the equation for your last parameter come from? I've always used Lindbloom's values and he gives 0.08. Best, Elle -- http://ninedegreesbelow.com Color management and free/libre photography ------------------------------------------------------------------------------ Mobile security can be enabling, not merely restricting. Employees who bring their own devices (BYOD) to work are irked by the imposition of MDM restrictions. Mobile Device Manager Plus allows you to control only the apps on BYO-devices by containerizing them, leaving personal data untouched! https://ad.doubleclick.net/ddm/clk/304595813;131938128;j _______________________________________________ Lcms-user mailing list Lcms-user@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/lcms-user