On Fri, 11 Jul 2008, Mo Beik wrote: > Hi > > I have installed v7.1.0g of the firmware for Sun Enterprise T5x20 > with LDOM 1.0.3. On the power down/OFF on the T5220, the second > virtual switch goes missing and has be be created and binded.
> Had to reconfigure -- > > root at brmcntrl1 # ldm add-vsw net-dev=e1000g1 primary-vsw1 primary > > Then bind guests and start . > > This only occurs when the system is power cycled . Does not happen with > normal reboot . > Any ideas why its losing its vsw1 config info ? After a poweroff, the saved config from the SP is restored (not the running config like a reboot). It's most probable that the saved config (ldm add-spconfig) does not incorporate the vsw, so when you poweroff, you come up in a config without it. If you do the ldm add-spconfig, and then poweroff/poweron, is it properly restored? -- Dave