In message <[email protected]>, Martin Burnicki writes:

>> The maximum offset with the linear smear was almost three times larger
>> than with the cosine smear. I think there is a different reason why
>> they switched to the linear smear.

I fear that test has sufficient power to reveal the full picture.

The NTPD PLL is quite temperamental, and when combined with the
median filter and a poll rate of 2048 seconds, things can get quite
"interesting".

I'm pretty sure that the linear smear interacts better with the
median filter at high poll intervals. 

>I'm going to run a test with a linear approach, too.

Please run it with "minpoll N maxpoll N" for N in (4...11)

-- 
Poul-Henning Kamp       | UNIX since Zilog Zeus 3.20
[email protected]         | TCP/IP since RFC 956
FreeBSD committer       | BSD since 4.3-tahoe    
Never attribute to malice what can adequately be explained by incompetence.