-------- In message <[email protected]>, Martin Burnicki writes:
>> The maximum offset with the linear smear was almost three times larger >> than with the cosine smear. I think there is a different reason why >> they switched to the linear smear. I fear that test has sufficient power to reveal the full picture. The NTPD PLL is quite temperamental, and when combined with the median filter and a poll rate of 2048 seconds, things can get quite "interesting". I'm pretty sure that the linear smear interacts better with the median filter at high poll intervals. >I'm going to run a test with a linear approach, too. Please run it with "minpoll N maxpoll N" for N in (4...11) -- Poul-Henning Kamp | UNIX since Zilog Zeus 3.20 [email protected] | TCP/IP since RFC 956 FreeBSD committer | BSD since 4.3-tahoe Never attribute to malice what can adequately be explained by incompetence. _______________________________________________ LEAPSECS mailing list [email protected] https://pairlist6.pair.net/mailman/listinfo/leapsecs