On Thu, 21 Aug 2014, Roy Stogner wrote:

> after renumbering takes place (e.g. in the Mesh construction or the
> EquationSystems reinit) then all the ids will be sequential.

It sounds like John just contradicted me, but really I just answered
the question you asked but he was smart enough to answer the question
you meant to ask: although element ids will be contiguous, some of
those ids will be of parent elements, so "active element" ids will
have gaps.
---
Roy

------------------------------------------------------------------------------