On Thu, 21 Aug 2014, Roy Stogner wrote: > after renumbering takes place (e.g. in the Mesh construction or the > EquationSystems reinit) then all the ids will be sequential.
It sounds like John just contradicted me, but really I just answered the question you asked but he was smart enough to answer the question you meant to ask: although element ids will be contiguous, some of those ids will be of parent elements, so "active element" ids will have gaps. --- Roy ------------------------------------------------------------------------------ Slashdot TV. Video for Nerds. Stuff that matters. http://tv.slashdot.org/ _______________________________________________ Libmesh-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/libmesh-users