On Thu, Sep 13, 2012 at 12:18 PM, John Chen <john...@gmail.com> wrote: > The timeout value for libusb_fill_bulk_transfer used to be 3 seconds, now > I set it to 15 seconds, it does not make any difference. >
What is the OS used here? If you are using Windows XP 32 bit, try Windows Vista or 7 (32bit or 64bit) to see if the problem still exists or not. If your apps are okay under Windows Vista and Windows 7, this might be related to the fact that CancelIoEx() is not availability under Windows XP. I am just guessing here. -- Xiaofan ------------------------------------------------------------------------------ Live Security Virtual Conference Exclusive live event will cover all the ways today's security and threat landscape has changed and how IT managers can respond. Discussions will include endpoint security, mobile security and the latest in malware threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/ _______________________________________________ libusbx-devel mailing list libusbx-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/libusbx-devel