Frank,

I would make sure that your MTU size and TCP/IP buffersizes are the same on
both sides of the connection.  The defaults for the two operating systems
are different, so if you don't specify them, you will likely experience
problems.

Mark Post

-----Original Message-----
From: Frank Schwede, LSY [mailto:[EMAIL PROTECTED]]
Sent: Tuesday, April 02, 2002 6:44 AM
To: [EMAIL PROTECTED]
Subject: vCTC Connection RH7.1 64bit Linux to zVM4.2 (RX/TX handshake
erro r)


Hello!

I succeed in couple CTC pairs in zVM, but in the booted Linux I get "Error
during RX init handshake"

Where I am wrong? Whats with that handshake error?


I did it like that (configs/profiles at bottom of mail)...

login with li1000:

LOGON LI1000
02: z/VM Version 4 Release 2.0, Service Level 0101 (64-bit),
02: built on IBM Virtualization Technology
02: There is no logmsg data
02: FILES:   NO RDR,   NO PRT,   NO PUN
02: RECONNECTED AT 12:31:12 EST TUESDAY 04/02/02
> i cms
z/VM V4.2.0    2002-01-29 09:09
DMSVML2060I TCPMAINT 592 linked as 0120 file mode Z
02: CTCA 1000 COUPLED TO VMIP 1001
02: CTCA 1001 COUPLED TO VMIP 1000
Ready; T=0.01/0.01 12:31:33


then "IPL 946C"
after IPL and logon to Linux and:

[root@linuxgigaxa root]# insmod ctc
insmod ctc
Using /lib/modules/2.4.7-0.24.23tape/kernel/drivers/s390/net/ctc.o
[root@linuxgigaxa root]#
[root@linuxgigaxa root]# ifconfig ctc0 57.20.91.169
ifconfig ctc0 57.20.91.169
ctc0: Error during TX init handshake
ctc0: Error during RX init handshake
[root@linuxgigaxa root]#

after a while (2 min?):
[root@linuxgigaxa root]# CTCA 1001 DROPPED BY VMIP 1000
CTCA 1000 DROPPED BY VMIP 1001

...and the VMIP guest is dropped from zVM.

I have to "halt" linux li1000, "disc" li1000 , login with AUTOLOG1 to get
VMIP up again, and login with li1000 again to get the CTC coupled again...






Configurations...


**TCPMAINT:Profile.tcpip**
DEVICE LI1000  CTC 1000
LINK   ZVMVC1000  CTC 0     LI1000

HOME
  57.20.91.170 ZVMVC1000

GATEWAY
  57.20.91.169  =            ZVMVC1000 1492         HOST


**MAINT:User.direct:**
USER VMIP VMIP 32M 128M ABG
  INCLUDE TCPCMSU
  OPTION QUICKDSP SVMSTAT MAXCONN 1024 DIAG98 APPLMON
  SHARE RELATIVE 3000
  IUCV ALLOW
  IUCV ANY PRIORITY
  IUCV *CCS PRIORITY MSGLIMIT 255
  SPECIAL 1000 CTCA LI1000
  SPECIAL 1001 CTCA LI1000
  LINK TCPMAINT 592 592 RR * TCPIP tools disk
  MDISK 191 3390 0096 001 420W02  MR READ     WRITE    MULTIPLE

USER Li1000 Li1000 256M 512M G
 MACHINE esa
 ACCOUNT 1234
 CPU 00 VECTOR
 CPU 02 NOVECTOR BASE
 IPL CMS PARM AUTOCR
 IUCV ANY
 IUCV ALLOW
 CONSOLE 009 3215
 SPOOL 00C 2540 READER *
 SPOOL 00D 2540 PUNCH A
 SPOOL 00E 1403 A
 LINK MAINT 0190 0190 RR * CMS system disk
 LINK MAINT 019D 019D RR * help disk
 LINK MAINT 019E 019E RR * Product code disk
 SPECIAL 1000 CTCA VMIP
 SPECIAL 1001 CTCA VMIP
 DEDICATE 92EB 92EB
 DEDICATE 946C 946C
 MDISK 191 3390 3336 001 420W01  MR READ     WRITE    MULTIPLE



/*PROFILE Li1000*/
'SET PF12 RETR'
/*'IPL 946B'*/
'VMFCLEAR'
'CP SET MSG ON'
'CP SET EMSG ON'
'SET IMPCP ON'
'SET RUN ON'
'CP TERM CHARDEL OFF'
'VMLINK TCPMAINT 592 ( NONAMES'
'CP SET PF10 RETR'
'CP SET RETR MAX'
'CP TERM HOLD OFF'
'CP COUPLE 1000 VMIP 1001'
'CP COUPLE 1001 VMIP 1000'






> Frank Schwede
> Product Manager IBM High-End System Software
>
> Lufthansa Systems Infratec GmbH
> FRA AR / ISS (IBM System Services)
> Am Weiher 24, Geb. B, Raum 7.1.18
> D 65451 Kelsterbach
>
> Tel   +49 69 696 94878
> Fax  +49 69 696 93488
> mailto:[EMAIL PROTECTED]
> http://www.LHsystems.com
>
>