WWWFGGHHTTYYUIOP
----- Original Message -----
From: "Peter Webb, Toronto Transit Commission" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Tuesday, April 02, 2002 1:27 PM
Subject: Re: vCTC Connection RH7.1 64bit Linux to zVM4.2 (RX/TX handshake
erro r)


> It looks like you have a problem in your VMIP virtual machine. The events
> you describe suggest that VMIP is abending and then getting forced off.
Try
> spooling the console for VMIP, and seeing if there is anything odd there.
>
> > -----Original Message-----
> > From: Frank Schwede, LSY [SMTP:[EMAIL PROTECTED]]
> > Sent: Tuesday, April 02, 2002 6:44 AM
> > To:   [EMAIL PROTECTED]
> > Subject:      vCTC Connection RH7.1 64bit Linux to zVM4.2 (RX/TX
handshake
> > erro r)
> >
> > Hello!
> >
> > I succeed in couple CTC pairs in zVM, but in the booted Linux I get
"Error
> > during RX init handshake"
> >
> > Where I am wrong? Whats with that handshake error?
> >
> >
> > I did it like that (configs/profiles at bottom of mail)...
> >
> > login with li1000:
> >
> > LOGON LI1000
> > 02: z/VM Version 4 Release 2.0, Service Level 0101 (64-bit),
> > 02: built on IBM Virtualization Technology
> > 02: There is no logmsg data
> > 02: FILES:   NO RDR,   NO PRT,   NO PUN
> > 02: RECONNECTED AT 12:31:12 EST TUESDAY 04/02/02
> > > i cms
> > z/VM V4.2.0    2002-01-29 09:09
> > DMSVML2060I TCPMAINT 592 linked as 0120 file mode Z
> > 02: CTCA 1000 COUPLED TO VMIP 1001
> > 02: CTCA 1001 COUPLED TO VMIP 1000
> > Ready; T=0.01/0.01 12:31:33
> >
> >
> > then "IPL 946C"
> > after IPL and logon to Linux and:
> >
> > [root@linuxgigaxa root]# insmod ctc
> > insmod ctc
> > Using /lib/modules/2.4.7-0.24.23tape/kernel/drivers/s390/net/ctc.o
> > [root@linuxgigaxa root]#
> > [root@linuxgigaxa root]# ifconfig ctc0 57.20.91.169
> > ifconfig ctc0 57.20.91.169
> > ctc0: Error during TX init handshake
> > ctc0: Error during RX init handshake
> > [root@linuxgigaxa root]#
> >
> > after a while (2 min?):
> > [root@linuxgigaxa root]# CTCA 1001 DROPPED BY VMIP 1000
> > CTCA 1000 DROPPED BY VMIP 1001
> >
> > ...and the VMIP guest is dropped from zVM.
> >
> > I have to "halt" linux li1000, "disc" li1000 , login with AUTOLOG1 to
get
> > VMIP up again, and login with li1000 again to get the CTC coupled
again...
> >
> >
> >
> >
> >
> >
> > Configurations...
> >
> >
> > **TCPMAINT:Profile.tcpip**
> > DEVICE LI1000  CTC 1000
> > LINK   ZVMVC1000  CTC 0     LI1000
> >
> > HOME
> >   57.20.91.170 ZVMVC1000
> >
> > GATEWAY
> >   57.20.91.169  =            ZVMVC1000 1492         HOST
> >
> >
> > **MAINT:User.direct:**
> > USER VMIP VMIP 32M 128M ABG
> >   INCLUDE TCPCMSU
> >   OPTION QUICKDSP SVMSTAT MAXCONN 1024 DIAG98 APPLMON
> >   SHARE RELATIVE 3000
> >   IUCV ALLOW
> >   IUCV ANY PRIORITY
> >   IUCV *CCS PRIORITY MSGLIMIT 255
> >   SPECIAL 1000 CTCA LI1000
> >   SPECIAL 1001 CTCA LI1000
> >   LINK TCPMAINT 592 592 RR * TCPIP tools disk
> >   MDISK 191 3390 0096 001 420W02  MR READ     WRITE    MULTIPLE
> >
> > USER Li1000 Li1000 256M 512M G
> >  MACHINE esa
> >  ACCOUNT 1234
> >  CPU 00 VECTOR
> >  CPU 02 NOVECTOR BASE
> >  IPL CMS PARM AUTOCR
> >  IUCV ANY
> >  IUCV ALLOW
> >  CONSOLE 009 3215
> >  SPOOL 00C 2540 READER *
> >  SPOOL 00D 2540 PUNCH A
> >  SPOOL 00E 1403 A
> >  LINK MAINT 0190 0190 RR * CMS system disk
> >  LINK MAINT 019D 019D RR * help disk
> >  LINK MAINT 019E 019E RR * Product code disk
> >  SPECIAL 1000 CTCA VMIP
> >  SPECIAL 1001 CTCA VMIP
> >  DEDICATE 92EB 92EB
> >  DEDICATE 946C 946C
> >  MDISK 191 3390 3336 001 420W01  MR READ     WRITE    MULTIPLE
> >
> >
> >
> > /*PROFILE Li1000*/
> > 'SET PF12 RETR'
> > /*'IPL 946B'*/
> > 'VMFCLEAR'
> > 'CP SET MSG ON'
> > 'CP SET EMSG ON'
> > 'SET IMPCP ON'
> > 'SET RUN ON'
> > 'CP TERM CHARDEL OFF'
> > 'VMLINK TCPMAINT 592 ( NONAMES'
> > 'CP SET PF10 RETR'
> > 'CP SET RETR MAX'
> > 'CP TERM HOLD OFF'
> > 'CP COUPLE 1000 VMIP 1001'
> > 'CP COUPLE 1001 VMIP 1000'
> >
> >
> >
> >
> >
> >
> > > Frank Schwede
> > > Product Manager IBM High-End System Software
> > >
> > > Lufthansa Systems Infratec GmbH
> > > FRA AR / ISS (IBM System Services)
> > > Am Weiher 24, Geb. B, Raum 7.1.18
> > > D 65451 Kelsterbach
> > >
> > > Tel   +49 69 696 94878
> > > Fax  +49 69 696 93488
> > > mailto:[EMAIL PROTECTED]
> > > http://www.LHsystems.com
> > >
> > >
>

Reply via email to