Lon,

We use dirmaint to allocate mdisks, so overwriting cylinder zero should
not be an issue. Good suggestion, though.

Michael Lambert



Date:    Tue, 15 Oct 2002 10:42:43 -0400
From:    "Loren Charnley, Jr." <[EMAIL PROTECTED]>
Subject: Re: Dasd partition disappeared

Michael,

Have you looked at the definition of the minidisk in the directory?  If
you
have a VM label on the disk, it will be on cylinder 0. The minidisk
should
start on cylinder 1 or above or the VM label will be overwritten and the
next time you IPL (reboot), LINUX will not be able to find the DASD
because
it will be looking for the VM label first. Just a thought, it has
already
happened to me.

Loren Charnley, Jr.
Tech Support Administrator
Family Dollar Stores, Inc.
Phone:  (704) 847-6961 Ext. 2000

Reply via email to