The first IPL record must be the next record on the tape when the IPL is issued. This error shows that it is not. Check your tape position.
If you rewind the tape before you write the IPL record and then rewind the tape just before the IPL you will avoid this error. Stephen Frazier Oklahoma Department of Corrections -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Steve Dorfman Sent: Wednesday, January 29, 2003 11:13 AM To: [EMAIL PROTECTED] Subject: Sles7-beta install kernal problem After creating a the IPable tape to get the install kernal booted I get the following message: HCPVMJ232E IPL UNIT ERROR; IRB 00404017 00020868 0D000018 00800000 HCPGIR450W CP entered; disabled wait PSW 000E0000 00000232