Thanks for all the great responses. I figured this could be accomplished and I am not surprised there is more than 1 method to be reviewed. Every response is helpful and will save me a lot of running around. Thanks Again, Al
-----Original Message----- From: Alan Altmark [mailto:[EMAIL PROTECTED] Sent: Wednesday, December 08, 2004 5:47 PM To: [EMAIL PROTECTED] Subject: Re: VIPA and hot standby On Wednesday, 12/08/2004 at 04:21 CST, Adam Thornton <[EMAIL PROTECTED]> wrote: > On Dec 8, 2004, at 4:17 PM, Rich Smrcina wrote: > > > Perhaps the right combination of special priviledge class and the hcp > > module would help. > > > You'd need to modify heartbeat-stonith's source to execute "hcp FORCE > user WITHIN interval" but it shouldn't be hard. I don't remember > whether the actual "shoot the other node" code is modular, but I'd > think it must be, because pulling the plug must have a bunch of > different interfaces. Maybe you just need to write a VM plugin for it. Now y'all cut that out. Use the z/VM System Management APIs; that's what they're for. No need to give the HA monitors all that privilege. Alan Altmark z/VM Development IBM Endicott ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390 ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390