Hi Jan, >How and where do we get that WWPN >Our storage guys do not understand our question
Storage guys that do not know what wwpn's are? Get new storage guys ;-)) Seriously, to start with basics: - is your switch a Fibre channel switch and not a Ficon-only one? - do they have fibre ports on the Symmetrix set to FC protocol? (If they don't know about wwpn's there is a fair chance they didn't) - do you have Ficon port set to type FCP on your zSeries? Best regards, Pieter Harder [email protected] tel +31-73-6837133 / +31-6-47272537 Brabant Water N.V. Postbus 1068 5200 BC 's-Hertogenbosch http://www.brabantwater.nl Handelsregister: 16005077 ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390