Hi Jan,

>How and where do we get that WWPN
>Our storage guys do not understand our question

Storage guys that do not know what wwpn's are? Get new storage guys ;-))

Seriously, to start with basics:
- is your switch a Fibre channel switch and not a Ficon-only one?
- do they have fibre ports on the Symmetrix set to FC protocol? (If they don't 
know about wwpn's there is a fair chance they didn't)
- do you have Ficon port set to type FCP on your zSeries?

Best regards,
Pieter Harder