On 22.06.2010 20:39, Thang Pham wrote:
I dropped the first instance of the qeth module, and the
qeth: Unknown symbol qdio_synchronize
qeth: Unknown symbol do_QDIO
...

errors disappeared.  But the ERROR: Interface setup failed:
pumpSetupInterface failed: get link - 19: No such device error is still
there.  I am using dhcp in my custom initrd.

How exactly are you building your custom initrd? Does your custom built
initrd create and activate a ccwgroup device according to Chapter 7 in
http://public.dhe.ibm.com/software/dw/linux390/docu/lk33dd05.pdf? (post
the output of lsqeth). Are all required ccw devices available to Linux?
(post the output of lscss).


Regards,
  Peter Oberparleiter

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390
----------------------------------------------------------------------
For more information on Linux on System z, visit
http://wiki.linuxvm.org/