We need to add another VNIC to a LINUX guest so that we can test 2 adapte

rs simultaneously.

Is there anything we need to do other than add another SPECIAL to our

current VSWITCH configuration below:

The SYSTEM CONFIG defines vswitch

/* vswitch definitions*/

define vswitch lnxvsw1 portname lnxvsw1 rdev 9004

/* end of vswitch definition */

AUTOLOG1 Profile EXEC grants access for each lnux guest to this vswitch

'CP SET VSWITCH LNXVSW1 GRANT VLINUX1'

'CP SET VSWITCH LNXVSW1 GRANT VLINUX2'

'CP SET VSWITCH LNXVSW1 GRANT VLINUX3'

'CP SET VSWITCH LNXVSW1 GRANT VLINUX4' future

'CP SET VSWITCH LNXVSW1 GRANT VLINUX5' future

User DIRECT each linux quest has a special statement for the vNIC

USER VLINUX1 VLINUX1 2G 2G G

SPECIAL D000 QDIO 3 SYSTEM LNXVSW1 <-- virt

NIC

 USER VLINUX2 VLINUX2 512M 2G G

SPECIAL D000 QDIO 3 SYSTEM LNXVSW1 <-- virt NIC

SPECIAL 9108 QDIO 3 SYSTEM OSALAN

USER VLINUX3 VLINUX3 512M 2G G

SPECIAL D000 QDIO 3 SYSTEM LNXVSW1 <-- virt NIC


--
George Henke
(C) 845 401 5614

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390
----------------------------------------------------------------------
For more information on Linux on System z, visit
http://wiki.linuxvm.org/

Reply via email to