>>> On 12/16/2010 at 01:42 PM, "Scully, William P" <[email protected]> 
>>> wrote: 
> User error: The portname does matter!  I thought IBM previously relieved
> this requirement.  I guess I'm wrong.  When I change the portname in the
> "prm" file to "INTRANET" my RH 6 server will connect to the OSA device.

They did, to the extent that you no longer have to supply a portname unless 
someone else connected to the (virtual or real) OSA specified one, in which 
case they have to match.  Unless you're sharing virtual networks with z/OS, 
it's better to just not specify one at all.