>>> On 3/4/2014 at 03:16 PM, Tom Burkholder <[email protected]> wrote: 
> I just noticed that my DTCVSW2 controller is showing Error: BACKUP Not ready 
> from the q vswitch command (probably not a good thing).  Looks like the paths 
> are online. Does anybody know how to get the backup controller DTCVSW2 back 
> into a *ready* state (without taking an TCPIP burp or outage)?  This is a 
> z/VM 6.2 single VM system.

This question would likely get far more of a response on the IBMVM mailing 
list, but I'll give it a try.  The problem isn't with DTCVSW2, just RDEV 160.  
You should probably check to make sure it's got a cable plugged in, that the 
physical switch sees it, etc.  Perhaps look at the HMC to see if anything there 
shows problems with the card, etc.


Mark Post

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390
----------------------------------------------------------------------
For more information on Linux on System z, visit
http://wiki.linuxvm.org/