inevitable, since you are changing the order of processors in the channel
strip. in some setups, you will notice the click as this happens, in others
you will not.

i considered a design in which every possible metering point had a "tap"
already in place, but this doesn't work for the "custom" option, hence the
current design.


On Tue, Jun 18, 2013 at 6:52 AM, Fons Adriaensen <[email protected]>wrote:

> Anyone else noticed this:
>
> Ardour 3.1-3-g1606996: changing the meter source (in/pre/post/custom)
> in a mixer strip generates clicks in the audio output.
>
> ??
>
> Ciao,
>
> --
> FA
>
> A world of exhaustive, reliable metadata would be an utopia.
> It's also a pipe-dream, founded on self-delusion, nerd hubris
> and hysterically inflated market opportunities. (Cory Doctorow)
>
> _______________________________________________
> Linux-audio-dev mailing list
> [email protected]
> http://lists.linuxaudio.org/listinfo/linux-audio-dev
>
_______________________________________________
Linux-audio-dev mailing list
[email protected]
http://lists.linuxaudio.org/listinfo/linux-audio-dev