When i added -P like down here: fence_ipmilan -P -a xxxxxxxxlo -l admin -p xxxxxxxxx -M 'cycle' -v Everything works, server reboots. But how do i get this "-P" option included in fence_ipmilan. How should my cluster.conf look like..that's the question...
2011/3/3 שלום קלמר <[email protected]> > H. > > Maybe iLo3 dont support cycle. why not to use the default , which is > "onoff" . Try it > > I think its good enough . > > -M method > Method to fence (onoff or cycle). Default is onoff. Use cycle > in > case your management card will power off with default method > so > there will be no chance to power machine on by IPMI. > > > On Thu, Mar 3, 2011 at 3:53 PM, Mika i <[email protected]> wrote: > >> this works: >> ipmitool -H xxxxxilo -I lanplus -U admin -P xxxxxx chassis power cycle >> Server is rebooted..... >> >> but not this: >> root@fff fence_ipmilan -a xxxxxxxxlo -l admin -p xxxxxxxxx -M 'cycle' -v >> Rebooting machine @ IPMI:xxixxxxxilo...Spawning: '/usr/bin/ipmitool -I lan >> -H 'xxxxxxx' -U 'admin' -P 'xxxxx41!' -v chassis power status'... >> Spawning: '/usr/bin/ipmitool -I lan -H 'xxxxxxx' -U 'admin' -P 'xxxxxx1!' >> -v chassis power cycle'... >> Failed >> >> cluster.conf >> .... >> <method name="1"> >> <device lanplus="1" >> name="xxxxxx_xxxxdev" timeout="20"/> >> ...... >> >> <fencedevice agent="fence_ipmilan" auth="none" ipaddr="xxxxxxxilo" >> login="admin" method="cycle" name="xxxxuxx32_fencedev" passwd="xxxxx!"/> >> >> >> >> >> >> >> 2011/3/3 שלום קלמר <[email protected]> >> >> Hi. >>> for ilo3 testing you can use : >>> # fence_ipmilan -a 17x.3x.7x.1xx -p "password" -o status >>> >>> fence_ipmilan -h >>> usage: fence_ipmilan <options> >>> -A <authtype> IPMI Lan Auth type (md5, password, or none) >>> -a <ipaddr> IPMI Lan IP to talk to >>> -i <ipaddr> IPMI Lan IP to talk to (deprecated, use -a) >>> -p <password> Password (if required) to control power on >>> IPMI device >>> -P Use Lanplus >>> -S <path> Script to retrieve password (if required) >>> -l <login> Username/Login (if required) to control power >>> on IPMI device >>> -o <op> Operation to perform. >>> Valid operations: on, off, reboot, status >>> -t <timeout> Timeout (sec) for IPMI operation (default 20) >>> -C <cipher> Ciphersuite to use (same as ipmitool -C parameter) >>> -M <method> Method to fence (onoff or cycle (default onoff) >>> -V Print version and exit >>> -v Verbose mode >>> >>> If no options are specified, the following options will be read >>> from standard input (one per line): >>> >>> auth=<auth> Same as -A >>> ipaddr=<#> Same as -a >>> passwd=<pass> Same as -p >>> passwd_script=<path> Same as -S >>> lanplus Same as -P >>> login=<login> Same as -u >>> option=<op> Same as -o >>> operation=<op> Same as -o >>> action=<op> Same as -o >>> timeout=<timeout> Same as -t >>> cipher=<cipher> Same as -C >>> method=<method> Same as -M >>> verbose Same as -v >>> >>> >>> On Thu, Mar 3, 2011 at 12:21 PM, Mika i <[email protected]> wrote: >>> >>>> hmm. >>>> Okey: have someone good installation instructions to get this >>>> fence_ipmilan to >>>> work. >>>> 1. active IPMI/DCMI over LAN in iLo3 >>>> 2. what should i install in server to get fence_ipmilan to work >>>> Now if i test connection it shows like this. >>>> >>>> ipmitool -v -H 17x.3x.7x.1xx -I lanplus -U admin mc info >>>> Password: >>>> Get Auth Capabilities error >>>> Get Auth Capabilities error >>>> Error issuing Get Channel Authentication Capabilies request >>>> Error: Unable to establish IPMI v2 / RMCP+ session >>>> Get Device ID command failed >>>> >>>> Can someone help me! >>>> 2011/3/2 <[email protected]> >>>> >>>>> >>>>> >>>>> [email protected] wrote on 03/02/2011 10:07:38 AM: >>>>> >>>>> > Hi >>>>> > >>>>> > Is there a way to get cluster-suite Fence to work with Rhel 5.5 and >>>>> iLo3 >>>>> > I have now in both clusters rhel 5.5 version with: >>>>> > kernel 2.6.18-194.el5 >>>>> > cman-2.0.115-68.el5_6.1 >>>>> > >>>>> > But in fence state i get allways message: Unable to connect/login to >>>>> > fencing device >>>>> > >>>>> > Any help - or must i update the cluster to rhel 5.6? >>>>> >>>>> What fence agent are you using, fence_ilo? >>>>> You will need to use the fence_ipmilan agent for iLO3. >>>>> -- >>>>> Linux-cluster mailing list >>>>> [email protected] >>>>> https://www.redhat.com/mailman/listinfo/linux-cluster >>>>> >>>> >>>> >>>> -- >>>> Linux-cluster mailing list >>>> [email protected] >>>> https://www.redhat.com/mailman/listinfo/linux-cluster >>>> >>> >>> >>> -- >>> Linux-cluster mailing list >>> [email protected] >>> https://www.redhat.com/mailman/listinfo/linux-cluster >>> >> >> >> -- >> Linux-cluster mailing list >> [email protected] >> https://www.redhat.com/mailman/listinfo/linux-cluster >> > > > -- > Linux-cluster mailing list > [email protected] > https://www.redhat.com/mailman/listinfo/linux-cluster >
-- Linux-cluster mailing list [email protected] https://www.redhat.com/mailman/listinfo/linux-cluster