On Mon, Nov 04, 2002 at 06:48:03PM +0000, Stefan Huelswitt wrote: > > On 04 Nov 2002 Klaus Schmidinger <[EMAIL PROTECTED]> wrote: > > This could be. Playing around with sectional filters I found such > a behaviour. If you setup such a filter and there is no data > available, you get a "connection timed out" error after about 30 > seconds and no further data is delivered even if there is data > later. The only way to get data, is to stop and restart the > filter.
Hm, the timeout timer is started only if you set the filter with dmx_sct_filter_params.timeout != 0. Once the timeout triggers, the filter will be stopped and must be restarted explicitly. > May be this applies to PES filters too. It may be more > complicated, as we doesn't read the filter directly but throught > the DVR device. PES filters have no timeout. Regards, Johannes -- Info: To unsubscribe send a mail to [EMAIL PROTECTED] with "unsubscribe linux-dvb" as subject.