On 05 Nov 2002 Johannes Stezenbach <[EMAIL PROTECTED]> wrote: > On Mon, Nov 04, 2002 at 06:48:03PM +0000, Stefan Huelswitt wrote: >> >> This could be. Playing around with sectional filters I found such >> a behaviour. If you setup such a filter and there is no data >> available, you get a "connection timed out" error after about 30 >> seconds and no further data is delivered even if there is data >> later. The only way to get data, is to stop and restart the >> filter. > > Hm, the timeout timer is started only if you set the filter > with dmx_sct_filter_params.timeout != 0. > Once the timeout triggers, the filter will be stopped and must > be restarted explicitly.
Indeed I set a timeout (can't remember why). Could it be, that in pre-NEWSTRUCT versions the timeout didn't worked? -- Stefan Huelswitt [EMAIL PROTECTED] | http://home.pages.de/~nathan -- Info: To unsubscribe send a mail to [EMAIL PROTECTED] with "unsubscribe linux-dvb" as subject.