On Jan 18, 2008, at 1:26 PM, Thomas Glanzmann wrote:
Lars,
Assuming that the fencing device can be reached from all nodes, it
doesn't matter where they are put. Only if you have, say, a serial
power
switch which is only reachable from one node do you need location
constraints.
I have a two node cluster. I use external/ipmi which needs one
instance
per node. A node that is misbehaving can't stonith itself, can it?
no
Is linux-ha so smart to see that the one stonith resource has to run
on
the one node and the other on the other node?
not quite _that_ smart
but since fencing doesn't require quorum, i _think_ we'd try and start
the stonith agent on the surviving node and start shooting...
so it should all work out eventually
_______________________________________________
Linux-HA mailing list
[email protected]
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems