On Sun, 17 Feb 2008, Michael Brennen wrote:
Heartbeat 2.1.3, crm enabled
I've built an initial drbd master/slave on two systems, lvc7 and
lvc8, following http://www.linux-ha.org/DRBD/HowTov2. The drbd is
coming alive in P/S mode, but it will not fail over when I kill
the master; the slave stays in secondary. stonith was not
working, so I've decided to make that work in v2 (I had it working
in a v1 build about a month ago.)
.....
Then, I am trying to define the stonith device in xml; the source to the
apc3.xml file is attached. I am adding from a separate command line:
Just to clear this up, I found my own silly problem: I had
misspelled one of the parameters (password, not passwd) for the
apcmaster stonith device in the xml.
The stonith daemons start successfully now, but with a monitor
interval of 15s one of the two fails fairly quickly. The apc (9211
masterswitch) only allows a single login, and I wonder if the two
daemons aren't colliding, and one is timing out and giving up.
Fortunately this is a test cluster; from what I have seen I would
never put this pdu in production. I will work with an external/ssh
stonith setup to see if I can't avoid the problems with the apc.
-- Michael
_______________________________________________
Linux-HA mailing list
[email protected]
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems