It depends on how you have your network set up. You could assign an
internal ip to your 10gig interfaces (something that isn't on your
existing network). You could then ping that ip from the other node and
use it's pingd score to base your constraint on.
Brandon
Kevin Harms wrote:
I have a set of servers that have two interfaces, 1 is the primary
10GE NIC and the other is a 1GE NIC. I'd like to minimize the
occurrence of STONITH by using both interfaces for heartbeat. I
understand that i would just add two mcast entries in the ha.cf file.
My question becomes that my application only uses the high speed
interface so the app needs to failover if that interface is down. Is
there a monitoring script that exists already that would provide this?
It seems like the intent of pingd is slightly different.
thanks,
kevin
_______________________________________________
Linux-HA mailing list
[email protected]
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems
_______________________________________________
Linux-HA mailing list
[email protected]
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems