Also seen in logs with the pacemaker 1.1.5: the point was unequal MTU settings 
between the 
servers ;-)
After setting the same MTU  on both NICs, all was working like a charm!


Have a nice day!


Nikita Michalko       


Am Mittwoch, 5. Juni 2013 14:25:19 schrieb Ulrich Windl:
> Hi!
> 
> When the cluster (SLES11 SP2, current) was put in maintenance mode, two
>  messages repeat periodically, filling the log: ERROR: crm_timer_popped:
>  Election Timeout (I_ELECTION_DC) just popped in state S_RELEASE_DC!
>  (120000ms) WARN: do_log: FSA: Input I_ELECTION_DC from crm_timer_popped()
>  received in state S_RELEASE_DC
> 
> crmd: [7285]: info: handle_request: Current ping state: S_RELEASE_DC
> 
> Is this expected, or is it yet another bug (pacemaker-1.1.7-0.13.9)?
> 
> Regards,
> Ulrich
> 
> 
> _______________________________________________
> Linux-HA mailing list
> [email protected]
> http://lists.linux-ha.org/mailman/listinfo/linux-ha
> See also: http://linux-ha.org/ReportingProblems
> 
_______________________________________________
Linux-HA mailing list
[email protected]
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems

Reply via email to